Technical and organizational measures
The following sections provide information about Maxon’s technical and organizational measures referred to in our Data Processing Addendum.
Document Management
Maxon will ensure that the necessary documentation is in place between Maxon and the User where Maxon processes Personal Data on behalf of the User. In the event of a change to the defined scope, any modification to the processing of Personal Data will be reviewed to determine the impact on required TOMs and other contract exhibits.
Information Security
Maxon implemented an Information Security Management System (ISMS) based on ISO/IEC 27001 and holds an ISO27001 certification, with the current certificate set to expire on January 8, 2028. Maxon employs certified Information Security and IT-security specialists with credentials such as CISSP, CISM, CIPM (IAPP), and CEH.
Security Incidents
Maxon maintains an incident response plan and follows documented incident response policies. This includes notifying Users about data breaches without undue delay when a breach is known or reasonably suspected to affect User Personal Data.
Risk Management
Maxon assesses risks related to the processing of personal data and develops action plans to mitigate identified risks.
List of TOMs
(DC) = Data Center control
(O) = Office control
For services hosted with cloud providers, physical and environmental datacenter controls are provided by the respective provider.
1. Confidentiality
1.1. Physical Access Control
Measures suitable for preventing unauthorized persons from gaining access to data processing systems with which Personal Data are processed or used.
Technical Measures
- Alarm system (DC/O)
- Automatic access control system (DC/O)
- Biometric access control (DC)
- Smart cards / transponder systems (DC/O)
- Manual locking system (O)
- Doorbell system with camera (DC/O)
- Video surveillance of entrances (DC/O)
- Physical perimeter barriers (DC)
Organizational Measures
- Key regulation / List (DC/O)
- Reception (DC/O)
- Gatekeeper and guards (DC)
- Visitors' book / Visitors' protocol (DC/O)
- Employee / visitor badges (DC)
- Visitors accompanied by employees (DC/O)
- Care in selection of security guard personnel (DC/O)
- Care in selection of cleaning services (DC/O)
- Information Security Policy (DC/O)
- Work instructions for operational safety (DC/O)
- Work instruction access control (DC/O)
1.2. Logical Access Control
Measures suitable for preventing data processing systems from being used by unauthorized persons.
Technical Measures
- Login with username, strong password, and MFA (DC/O)
- Anti-virus software servers / EDR (DC/O)
- Anti-virus software clients / EDR (DC/O)
- Firewall (DC/O)
- Next-generation email security tools (O)
- Intrusion Detection Systems (DC/O)
- Intrusion Prevention Systems (DC/O)
- Attack Surface Management / ASM (DC/O)
- Cloud Security Posture Management (DC/O)
- Annual penetration testing (DC/O)
- Secure Access Service Edge / SASE (DC/O)
- Zero-Trust principle (DC/O)
- Encryption in transit (DC/O)
- HDD encryption (DC/O)
- Backup encryption (DC/O)
- User Cloud Content encrypted at rest (DC)
- Secure configuration and hardening (DC/O)
- Malware protection, web filtering and data leakage prevention (DC/O)
- Vulnerability scanning and patching within defined time limits by risk rating (DC/O)
- File integrity monitoring (DC/O)
- Automated GRC platform (DC/O)
Organizational Measures
- Role-based Access Control / RBAC (DC/O)
- User life cycle management (DC/O)
- Strict password policies (DC/O)
- Work instruction IT user regulations (DC/O)
- Work instruction operational security (DC/O)
- Work instruction access control (DC/O)
- Access reviews and password manager log reviews twice a year (O)
- Segregation of duties, unique user IDs and separate accounts for administrative use (O)
- Confidentiality agreements and due diligence for employees and relevant contractors with access to Maxon or customer information (O)
- Defined termination and disciplinary processes (O)
- Mandatory information security awareness training for all employees (DC/O)
- ISMS policies certified ISO/IEC 27001:2022(E) (DC/O)
1.3. Authorization Control
Measures to ensure that those authorized to use a data processing system can only access the data subject to their access authorization and that Personal Data cannot be read, copied, modified or removed without authorization during processing, use and after storage.
Technical Measures
- Secure destruction of files (DC/O)
- Physical deletion of data carriers (DC/O)
- Logging of accesses to applications (DC/O)
- Centralized logfile server (DC/O)
Organizational Measures
- Following Need-to-Know principle (DC/O)
- Following Least-Privilege principle (DC/O)
- Access rights via strict process with documented approvals (DC/O)
- Minimum number of administrators (DC/O)
- Privileged access management (DC/O)
- Management of user rights by administrators (DC/O)
- Information Security Policy (DC/O)
- Work instruction communication security (DC/O)
- Work instruction handling of information (DC/O)
- Data Management Policy with data classification (DC/O)
1.4. Separation Control
Measures that ensure that data collected for different purposes can be processed separately. This can be ensured, for example, by logical and physical separation of the data.
Technical Measures
- Separation of productive, development and test environment (DC/O)
- Logical separation of systems (DC/O)
- VLAN segmentation (O)
- Client data logically separated (DC/O)
- Customer data anonymized in test environments (O)
Organizational Measures
- Control via authorization concept (DC/O)
- Determination of database rights (DC/O)
- Information Security Policy (DC/O)
- Data Protection Policy (DC/O)
- Work instruction operational security (DC/O)
- Work instruction security in software development (DC/O)
1.5. Pseudonymization
The processing of Personal Data in such a way that the data can no longer be attributed to a specific data subject without the use of additional information, provided that such additional information is kept separately and is subject to appropriate technical and organizational measures.
Technical Measures
- Relational databases using abstract identifiers (DC/O)
- Data masking / anonymization on deletion requests and when retention periods expire (O)
Organizational Measures
- Information Security Policy (DC/O)
- Data Protection Policy (DC/O)
2. Integrity
2.1. Transfer Control
Measures to ensure that Personal Data cannot be read, copied, altered or removed by unauthorized persons during electronic transmission or while being transported or stored on data media, and that it is possible to verify and establish to which entities Personal Data are intended to be transmitted by data transmission equipment.
Technical Measures
- Secure Access Service Edge / SASE encrypted tunnels (DC/O)
- Logging of accesses (DC/O)
- Encryption in transit (DC/O)
- Centralized logfile server (DC/O)
Organizational Measures
- Defined change management processes (DC/O)
- Work instruction to only use encrypted transfer (DC/O)
- No physical data transfer permitted (DC/O)
- Information Security Policy (DC/O)
- Data Protection Policy (DC/O)
2.2. Input Control
Measures that ensure that it is possible to check and establish retrospectively whether and by whom Personal Data has been entered into, modified or removed from data processing systems. Input control is achieved through logging, which can take place at various levels (e.g., operating system, network, firewall, database, application).
Technical Measures
- Technical logging of entry, modification, and deletion of data (DC/O)
- Centralized logfile server (DC/O)
- Administrator, operator and data restore logs with synchronized clocks (DC/O)
- Log retention of at least one financial reporting period (DC/O)
Organizational Measures
- Restriction of roles who can enter, change, or delete data (DC/O)
- Non-repudiation controls / named user accounts only (DC/O)
- Strict and documented authorization concept (DC/O)
- Clear responsibilities for deletions (DC/O)
- Restoration of production Personal Data logged in auditable tickets (O)
- Information Security Policy (DC/O)
- Work instruction IT user regulations (DC/O)
3. Availability and Resilience
3.1. Availability Control
Measures to ensure that Personal Data is protected against accidental destruction or loss.
Technical Measures
- Environmental protection (DC)
- Alarm and surveillance systems (DC/O)
- Cloud backup concept (DC/O)
- Failover and High-Availability (DC)
- Content delivery network / CDN (DC)
Organizational Measures
- Business Continuity Management System / BCMS (DC/O)
3.2. Recoverability Control
Measures capable of rapidly restoring the availability of and access to Personal Data in the event of a physical or technical incident.
Technical Measures
- Backup monitoring and reporting (DC/O)
- Backup concept according to business criticality (DC/O)
- Automated granular backup and recovery tools (DC/O)
- Backups stored separately from the production data location (DC/O)
- Backup and recovery capabilities tested at least annually (DC/O)
Organizational Measures
- Business Continuity Management System / BCMS (DC/O)
- Business impact assessment and criticality tiering of systems and services (O)
- Information Security Policy (DC/O)
4. Procedures for regular Review, Assessment and Evaluation
4.1. Data Protection Management
Technical Measures
- Central documentation of all data protection regulations and policies (O)
- Documentation of TOMs (O)
- Automated GRC platform (DC/O)
Organizational Measures
- Internal data protection experts (O)
- Mandatory data protection and privacy training for all staff (O)
- Data Protection Impact Assessments (DPIA) as required (O)
- Register of processing activities (O)
- Internal audits, management review and quarterly ISMS Steering Committee meetings (O)
4.2. Incident Response Management
Support for security breach response and data breach process.
Technical Measures
- Collection of relevant technical logfiles (DC/O)
- Dashboards with automated alerts and analysis (DC/O)
- Intrusion detection systems (DC/O)
- Centralized logfile server (DC/O)
- Certified security provider for ongoing EDR monitoring (DC/O)
Organizational Measures
- Information Security Policies with incident response procedures (DC/O)
- Formalized documentation of incident response and measures (DC/O)
- Work instruction IT user regulations (DC/O)
- Work instruction operational security (DC/O)
- On-demand certified third-party security provider during response (DC/O)
- Incident severity classification with defined response times (O)
- Breach notification workflow with Legal involvement, aligned with GDPR deadlines (O)
- Escalation of severe incidents to crisis management (O)
4.3. Data Protection by Design and by Default
Measures pursuant to Article 25 GDPR that comply with the principles of data protection by design and by default.
Technical Measures
- Secure storage of Personal Data (DC/O)
- Technical implementation of user consent (DC)
Organizational Measures
- Data Privacy Policy (DC/O)
- Data minimization principle (DC/O)
- Purpose limitation principle (DC/O)
- Data storage limitation principle (DC/O)
- Data privacy in project management and system development (DC/O)
5. Third-Party Management
Measures to ensure that third parties processing Personal Data on behalf of Maxon provide sufficient guarantees of appropriate technical and organizational measures.
- Due diligence and security review before engagement, based on risk classification (O)
- Periodic review of third parties’ services and of changes to those services (O)
- Review of independent assurance reports and certifications of cloud providers (O)